Estérençuby Church: reading the GEOSTOP 60 follow-up report
18/11/2026
An ATE installed by the customer in Saint-Denis: neat and simple
18/11/2026This Humidistop France case file brings together the observations available for one building. It is intended to help property owners prepare a project from dated records, the construction materials and the conditions of each sample.
The Lourenties Church report follows three walls between installation on 8 July 2014 and the control on 12 October 2015. It provides a documented reference for contractors, local authorities and building managers organising a similar follow-up.
Measurements recorded in the report
| Sampling point | Initial record | Follow-up record |
|---|---|---|
| Rear wall | 7.8 gr/100 | 3.3 gr/100 |
| Right entrance wall | 8 gr/100 | 3.4 gr/100 |
| Left wall | 9.5 gr/100 | 2.5 gr/100 |
The values and units reproduce the report. Sample-mass headings and the stated units are not consistent, so no conversion to percentages or overall reduction is made. Samples are recorded at a depth of 20 cm, at a height of 48 cm for the rear wall and 40 cm for the other walls.
How to interpret the follow-up
The report describes lower readings and drying in progress. It also notes lateral water entry, a damaged gutter and standing water that need to be addressed separately. These observations belong in the case presentation alongside the table.
Preparing the next steps for your building
Before selecting equipment, locate the affected walls on a plan and separate rising damp from rainwater entry, plumbing leaks and condensation. Keep dated photographs and note any changes to gutters, drainage, ventilation or wall finishes. These details matter when discussing coverage and placement.
What can this reference establish?
The figures describe the sampled points and the visits stated in the document. They do not establish a uniform condition throughout a building. Where locations or sample conditions changed, keep that limitation alongside the result. Finishing work should follow the actual condition of the substrate and any salts remaining in it.
How should equipment be compared?
Compare the exact technical reference, its coverage diameter, installation instructions and power requirements. ATE equipment is electromagnetic and uses electricity; ATG equipment is geomagnetic and operates without a mains connection. Keep the historical model in the report distinct from a model currently on sale. Address other water sources as part of the project.
Other Humidistop France references
Source: Humidistop site report supplied for this reference. Conclusions are attributed to that document; readings retain their original units and sampling limits.
Exterior photograph: France64160, Wikimedia Commons, CC0. The building was photographed in 2011, independently of the inspection. Wikimedia Commons.
Choose your Humidistop device
Is your problem caused by rising damp? Discover the ATE and ATG ranges made in France, with a 10-year manufacturer’s warranty under the terms of the product pages. Compare models, coverage and direct factory prices to choose the reference suited to your home.